Sale of pumps: | sbyt@hms-livgidromash.ru |
Reception: |
lgm@hms-livgidromash.ru |
Centrifugal pumps CN 160/112 and CN 90/100 series and electric pump units on their base are intended for pumping fuels for jet engines in the pure state as per GOST 10227-86, GOST 12308-89 or with crystallization liquids up to 0,3% by mass (TGF – GOST 17477-86, TGFM – TU6-10-1457- 79, I – GOST 8313-88 and I-М TU 6-10-1457-79, motor spirit GOST 2084-77, aviation spirit GOST 1012-72 and diesel fuel GOST 305-82), and also water and other liquids similar to water at viscosity and chemical activity.
Pumps are repairable items of aspect 1 as per GOST 27.003-90.
Pumps and units are designed according to safety requirements as per GOST R 52743-2007.
Pumps (units) are admitted to handle liquids of IIА, IIV categories and Т1, Т2, Т3, Т4 explosibility groups as per GOST R 51330.19. It is admitted to instal electric pumps in explosion hazard zones of classV-Iа, V-Ib, V-Ig, V-IIА according to classification in Regulations for the Design and Construction of Electrical Installations .
CN pump - is centrifugal, double-suction ,horizontal , single-stage pump with double supply of the liquid to the impeller and with volute discharge.
The pump case has a joint in the horizontal plane passing through the rotor axis. The case cover extends the configuration of the case ducts.
For pumps CN 90/100, CN 90/100-Е, CN 160/112, CN 160/112-Е, CN 160/112-1, CN 160/112-Е-1( with bottom position of branch pipes) in the top of the case cover there is a hole М16х1,5 for connecting a vacuum pump or for linking up a vacuum treatment system.
For pumps CN 160/112-2, CN 160/112-Е-2, CN 160/112-3, CN 160/112-Е-3 (with top position of branch pipes) the hole for connecting a vacuum pump or for linking up a vacuum treatment system is installed on delivery branch pipe.
The main sense of rotation of the pump rotor is counter-clockwise left-handed (for pumps with bottom position of branch pipes) or clockwise right-handed (for pumps with top position of branch pipes). At the Customer's request the pumps with opposite rotation of the rotor, pumps with top position of branch pipes -with device for fastening and drive of tachometer sensor may be manufactured.
To prevent leakage of liquid over the shaft, provision is made in the pump for the end-face seal : single end-face seal with an auxiliary or double end-face seal.
Impeller – is of a double-entry type, thus, basically, it allows placing axial thrusts in equilibrium. The residual axial thrusts are taken up by the radial thrust bearings.
Pump models | Flow (nomin.), m³/h | Head, m | Pump power input (max.), kW | Rotation speed, rpm | Rotation speed, c˜¹ | Pump efficiency,% | Frequency, Hz | Type of current | Admissible positive suction head, m, max |
CN 90/100-E | 90 | 100 | 50 | 2900 | 48 | 55 | 50 | AC | 4.8 |
CN 90/100 | 90 | 100 | 44 | 2900 | 48 | 60 | 50 | AC | 4.8 |
CN 90/100a | 80 | 80 | 40 | 2900 | 48 | 60 | 50 | AC | 4.8 |
CN 90/100a-E | 80 | 80 | 45 | 2900 | 48 | 55 | 50 | AC | 4.8 |
CN 160/112 | 160 | 112 | 77 | 2900 | 48 | 70 | 50 | AC | 4.8 |
CN 160/112-E | 160 | 112 | 85 | 2900 | 48 | 65 | 50 | AC | 4.8 |
CN 160/112a | 150 | 100 | 62 | 2900 | 48 | 70 | 50 | AC | 4.8 |
CN 160/112a-E | 150 | 100 | 67 | 2900 | 48 | 65 | 50 | AC | 4.8 |
CN 160/112b | 135 | 80 | 50 | 2900 | 48 | 70 | 50 | AC | 4.8 |
CN 160/112b-E | 135 | 80 | 54 | 2900 | 48 | 65 | 50 | AC | 4.8 |
CN 160/112v-E-t | 135 | - | 46 | 2600 | 43 | 64 | 50 | AC | 4.4 |
Example: CN160/112v-Е-t U2 TU26-06-1640-91 , where :
All technical documentation in the Russian version of the site »
All certificates, permits in the Russian version of the site »
© Copyright 1999-2024. All rights reserved. When using materials from the site and permit the direct hyperlink on www.hms-livgidromash.com reserved.